Abdominal trauma and other pathology

Traumatic Injury

Trauma can be either blunt force or sharp penetrating trauma. Common mechanisms include high speed road traffic accidents, falls from height and assault. Both blunt and penetrating trauma types can cause solid organ, bowel and mesenteric injuries. In high energy trauma, a whole body (head/neck/chest/abdo/pelvis) trauma series CT with two phases of contrast enhancement is usually done.  Injuries to the liver, kidneys and spleen are associated with rib injuries. There may be a laceration with associated haematoma, with extension to involve the vessels at the hilum of the organ. There may also be active bleeding which would require emergent surgery or interventional radiology input to embolise the bleeding vessel.

Appearance: Disruption in continuity of the organ cortex, associated soft tissue injury, haematoma, contrast extravasation indicating active bleeding.

traumaabdo1.png
previous arrow
next arrow
traumaabdo1.png
traumaabdo2.png
traumaabdo3.png
previous arrow
next arrow

Gas in Peritoneum

Causes of gas/air within intra- or retroperitoneal spaces:

  • Perforation – of hollow viscus (usually duodenum or sigmoid)
  • Recent laparoscopic surgery – from CO2 insufflation

Appearance: Free air within the peritoneum.  Location of the air depends on the segment of perforated bowel i.e. intra- or retro-peritoneal. Air can extend into other spaces e.g. pneumomediastinum. Perforation of the rectum – air in mesorectum (mesentery surrounding rectum).

pneumoperitoneum1.png
previous arrow
next arrow
pneumoperitoneum1.png
pneumoperitoneum2.png
pneumoperitoneum3.png
previous arrow
next arrow

Gas in Bladder

Causes of gas within the urinary bladder:

  • Catheterisation – recent or current
  • Fistula – between bladder and bowel

A fistula would allow infecting organisms to easily colonise the bladder leading to frequent UTIs and pyelonephritis.

Appearance: Gas within the bladder, forming an air-fluid level with the urine inside the bladder.

gasinbladder1.png
previous arrow
next arrow
gasinbladder1.png
gasinbladder2.png
previous arrow
next arrow

Abdominal Aortic Aneurysm

Focal dilatation of the abdominal aorta. Two-thirds of patients with ruptured AAAs die before reaching hospital. Of those who make it to emergency surgery, half die. Ultrasound used for diagnosis and screening. CT used for suspected leak, but this must not delay emergency surgery.

Screening for AAA is offered to all men when they turn 65. It is a quick ultrasound scan to measure the abdominal aorta, done in the community.

  • If the test is negative (< 3 cm), there will be no further recall scans, unlike other screening programmes
  • If the test is positive (> 3 cm), further action depends on the diameter of the aneurysm: 3.0 – 4.4 cm = repeat in 1 year; 4.5 – 5.4 cm = repeat in 3 months; > 5.5 cm = immediate referral to vascular surgeons to consider elective repair
aaaruptured1.png
previous arrow
next arrow
aaaruptured1.png
aaaruptured2.png
previous arrow
next arrow

Appearance: Aneurysm wall usually calcified. If ruptured, free blood (higher density than fluid e.g. in stomach/GB) with possible contrast leak. Mural thrombus common, seen as circumferential low density area.

gynae1.png
previous arrow
next arrow
gynae1.png
gynae2.jpg
previous arrow
next arrow

Gynaecology

The preferred modality for initial diagnosis of a suspected gynaecological pathology is ultrasound (transabdominal or transvaginal).

Uterine fibroids can be very large and cause pain if they degenerate. Endometriosis may present as ovarian masses, partially cystic, or as deposits anywhere within the abdominal cavity.

Gynaecologic malignancies are staged with MRI & CT. Ovarian cancer tends to present late, frequently with spread to the peritoneum and omentum by diagnosis.

A ‘Krukenberg tumour’ refers to a metastatic deposit in the ovary which originated from a primary elsewhere within the peritoneal cavity.

Appearance: Uterine fibroids can calcify and are seen as rounded masses with calcific rims. MRI can show the blood within endometriotic deposits on ovaries and the rectovaginal space.

omental1.png
previous arrow
next arrow
omental1.png
omental2.jpg
previous arrow
next arrow

Peritoneal and Omental Disease

Soft tissue nodularity and thickening of the omentum and peritoneum can be seen in either metastatic disease (usually from gastric, pancreatic, colonic or ovarian carcinomas) or from infections such as tuberculosis. There may also be nodularity on the serosal surface of the bowel, and in metastatic disease in particular, the bowel may become encased in widespread malignant tissue. Ultrasound or CT guidance can be used to biopsy the omentum to identify the primary source.

Appearance: Nodular thickening of omentum deep to abdominal wall (“cake”) and peritoneal nodularity. Necrotic lymph nodes are a feature of TB.

ascites1.png
previous arrow
next arrow
ascites1.png
ascites2.png
ascites3.png
ascites4.png
ascites5.jpg
previous arrow
next arrow

Ascites

Ascites is seen in chronic liver disease, heart failure and abdominopelvic malignancies. It presents as abdominal distension.

It can be seen easily on ultrasound and CT.
Ultrasound guided paracentesis/drainage can be carried out. A sample of ascitic fluid can be obtained for laboratory testing.

Appearance: Depending on the quantity, it is usually seen as fluid around the liver and spleen, surrounding the bowel, and in the pelvic cavity. It travels to dependent locations, i.e. the left and right paracolic gutters (folds of peritoneum) posteriorly.